Unable to stop job in DataStage Director

Aysenur Karatay
2 min readMar 25, 2019

--

When we want to stop a running job in Director, sometimes it does not stop the job and the processes continue running.

To resolve the problem:

1- Go to Job -> Cleanup Resources in Director:

If this option is not enable, you can enable it in Infosphere Datastage Administration. To do this:

  • Select the Project and go to Properties. Then activate “Enable job administration in Director”

2- Return back to Cleanup Resources option. Find your item name from Locks menu and click Show by process:

3- Find PID id of your item from Processes menu and click Logout:

4- You can control if the job is stopped in Director:

--

--